What a panel order is made of
Every panel line on an order has five parts: the profile (PBR or R-panel in our catalog; other suppliers also sell AG and standing seam), the gauge, the color, the cut length of one sheet, and the number of sheets at that length.
PBR and AG sheets each cover 36 inches of width once installed. Standing seam panels come in several widths; your drawings show which one your building uses.
Roof panels: the length of one sheet
Measure along the slope of the roof, from the eave to the ridge, not across the building on the level. A tape laid on the purlins gives you the slope length directly.
Add any overhang your drawings show at the eave. If the run is longer than you want to handle as one sheet, panels can be lapped end to end; your drawings or the panel instructions say where laps go and how long they are.
Roof panels: how many sheets
Divide the length of the building (the run the sheets will cover, side to side) by 3 feet and round up. A gable roof has two sides, so count each side.
For example, a run of 61 feet needs 61 divided by 3, which is 20.3, so 21 sheets per side.
Wall panels: side walls and end walls
On a side wall every sheet is the same length: measure from the bottom of the base trim line to the top of the eave strut, then count sheets the same way as the roof.
End walls with a gable are different. Each sheet gets longer toward the peak, so list each length separately. Measure at the high edge of each sheet's 3-foot width so the slope cut has material to work with.
Writing it up
- One line per length: quantity, then length in feet and inches (for example, 21 at 24 ft 6 in).
- Group the lines by profile, gauge and color.
- Add the trim, closures and screws that go with the panels. Our other two guides cover those.
- In the cart, add each cut length as its own line.
Check before you send
- Feet and inches are in the right boxes.
- The color name matches the rest of the building. Shades vary by mill, and we confirm the match before cutting.
- Your engineering documents govern the profile, gauge and laps. If you are matching an existing building, tell us in the contact form (or email support@steeliumcomponents.com); we reply by email so you can send a photo of a panel end.
Your building's engineering documents govern sizes, gauges, spacing and connections. We supply parts to match them; we do not give engineering advice.